资源类型

期刊论文 177

会议视频 6

年份

2023 10

2022 24

2021 16

2020 17

2019 6

2018 8

2017 9

2016 8

2015 30

2014 8

2013 7

2012 4

2011 2

2010 7

2009 10

2008 5

2007 3

2005 2

2004 2

2002 2

展开 ︾

关键词

智能电网 6

可再生能源 3

乳液 2

海上风电 2

电力系统 2

电网 2

界面 2

能源 2

/III-V界面 1

5% 法 1

ACE2 1

GIC 1

GIS 1

Grid service 1

IEEE 2030.5 1

NASICON 1

SARS-CoV-2 1

WBS矩阵 1

Web service 1

展开 ︾

检索范围:

排序: 展示方式:

Feedback linearization based control for weak grid connected PV system under normal and abnormal conditions

Rahul SHARMA,Sathans SUHAG

《能源前沿(英文)》 2020年 第14卷 第2期   页码 400-409 doi: 10.1007/s11708-017-0459-5

摘要: This paper proposes a control strategy for interface of distributed energy sources into the weak grid system with a focus on the energy and ancillary services. A novel controller has been designed and implemented to tackle the challenges of coupling terms in the LCL filter, the transient behavior under sudden changes, and the voltage support under fault condition using the feedback linearization technique. The controller proposed has been implemented on the PV system connected with the weak grid using the LCL filter and the performance of the controller has been verified using Matlab/Simulink through simulation under different conditions. The results of the controller proposed have been compared with the conventional PI dual loop controller. The simulation results obtained demonstrate the effectiveness and simplicity of the controller design strategy.

关键词: PV system     grid interface     feedback linearization     inverter     LCL filter    

Effect of interface adhesion factor on the bearing capacity of strip footing placed on cohesive soil

《结构与土木工程前沿(英文)》 2021年 第15卷 第6期   页码 1494-1503 doi: 10.1007/s11709-021-0768-y

摘要: The problem related to bearing capacity of footing either on pure soil or on pure rock mass has been investigated over the years. Currently, no study deals with the bearing capacity of strip footing on a cohesive soil layer overlying rock mass. Therefore, by implementing the lower bound finite element limit analysis in conjunction with the second-order cone programming and the power cone programming, the ultimate bearing capacity of a strip footing located on a cohesive soil overlying rock mass is determined in this study. By considering the different values of interface adhesion factor (αcr) between the cohesive soil and rock mass, the ultimate bearing capacity of strip footing is expressed in terms of influence factor (If) for different values of cohesive soil layer cover ratio (Tcs/B). The failure of cohesive soil is modeled by using Mohr−Coulomb yield criterion, whereas Generalized Hoek−Brown yield criterion is utilized to model the rock mass at failure. The variations ofIf with different magnitudes of αcr are studied by considering the influence of the rock mass strength parameters of beneath rock mass layer. To examine stress distribution at different depths, failure patterns are also plotted.

关键词: bearing capacity     soil-rock interface     Hoek−Brown yield criterion     plasticity     limit analysis    

Experimental verification of the interface wave method to detect interlaminar damage of a metal multilayer

Bing LI,Xu GENG,Tong LU,Lei QIANG,Minghang LI

《机械工程前沿(英文)》 2015年 第10卷 第4期   页码 380-391 doi: 10.1007/s11465-015-0365-7

摘要:

The interface wave traveling along the boundary of two materials has been studied for nearly a century. However, experiments, engineering applications, and interface wave applications to the non-destructive inspection of interlaminar composite have developed slowly. In this research, an experiment that applies Stoneley waves (a type of interfacial wave between two solid half-spaces) is implemented to detect the damage in a multilayer structure. The feasibility of this method is also verified. First, the wave velocity and wave structure of Stoneley waves at a perfectly bonded aluminum-steel interface are obtained by solving the Stoneley wave dispersion equation of two elastic half-spaces. Thereafter, an experiment is conducted to measure the Stoneley wave velocity of an aluminum-steel laminated beam and to locate interlaminar cracks by referring to the Stoneley wave velocity and echo wave time. Results indicate that the location error is less than 2%. Therefore, Stoneley waves show great potential as a non-destructive inspection method of a multilayer structure.

关键词: crack localization     interface waves     Stoneley waves     interlaminar damage     multilayer structure    

Multi-objective optimization of surface texture for the slipperswash plate interface in EHA pumps

《机械工程前沿(英文)》 2022年 第17卷 第4期 doi: 10.1007/s11465-022-0704-4

摘要: Well-designed surface textures can improve the tribological properties and the efficiency of the electro-hydrostatic actuator (EHA) pump under high-speed and high-pressure conditions. This study proposes a multi-objective optimization model to obtain the arbitrarily surface textures design of the slipper/swash plate interface for improving the mechanical and volumetric efficiency of the EHA pump. The model is composed of the lubrication film model, the component dynamic model considering the spinning motion, and the multi-objective optimization model. In this way, the arbitrary-shaped surface texture with the best comprehensive effect in the EHA pump is achieved and its positive effects in the EHA pump prototype are verified. Experimental results show a reduction in wear and an improvement in mechanical and volumetric efficiency by 1.4% and 0.8%, respectively, with the textured swash plate compared with the untextured one.

关键词: electro-hydrostatic actuator     axial piston pump     slipper/swash plate interface     multi-objective optimization     surface texture    

Thermal analysis of lubricated three-dimensional contact bodies considering interface roughness

《机械工程前沿(英文)》 2022年 第17卷 第2期 doi: 10.1007/s11465-022-0672-8

摘要: Surface roughness and thermal action are of remarkable importance in the lubrication performance of mechanical components, especially in extreme conditions. However, available studies mainly focus on the full-film lubrication conditions without considering temperature rise and real 3D surface roughness due to the complexity of surface topography and temperature characteristics. Moreover, studies on the interfacial thermal behaviors of 3D rough surface lubricated contact in an extended range of working conditions remain limited. In this paper, a deterministic mixed thermal elastohydrodynamic lubrication model considering real 3D surface roughness and thermal effects is proposed. In this model, pressure and temperature are coupled with each other, the computation of elastic deformation is accelerated through the discrete convolution and fast Fourier transform method, the temperature field is calculated with the column sweeping technique, and the semi-system method is introduced to improve convergence and numerical stability under severe conditions. The model is validated by comparing its results with available published numerical and experimental results. The thermal behaviors of the contact interface are studied in a wide range of working conditions. The influences of surface roughness and thermal effect on lubrication performance are revealed. The results show that the proposed model can be used as a powerful analysis tool for lubrication performance and temperature prediction in various heavy-load, high-speed lubricated components over a wide range of lubrication conditions.

关键词: thermal elastohydrodynamic lubrication     surface roughness effect     thermal effect     temperature characteristics     severe conditions    

Optimal placement of PMUs for the smart grid implementation in Indian power grid—A case study

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

《能源前沿(英文)》 2013年 第7卷 第3期   页码 358-372 doi: 10.1007/s11708-013-0257-7

摘要: Efficient utilization of energy resources is essential for a developing country like India. The concept of smart grid (SG) can provide a highly reliable power system with optimized utilization of available resources. The present Indian power grid requires revolutionary changes to meet the growing demands and to make the grid smarter and reliable. One of the important requirements for SG is the instantaneous monitoring of the voltage, current and power flows at all buses in the grid. The traditional monitoring system cannot satisfy this requirement since they are based on nonlinear power flow equations. Synchro-phasor-measurement devices like phasor measurement units (PMUs) can measure the phasor values of voltages at installed buses. Consequently, the currents passing through all branches connected to that bus can be computed. Since the voltage phasor values at the neighboring buses of a bus containing the PMU can be estimated using Ohm’s law, it is redundant to install PMUs at all the buses in a power grid for its complete observability. This paper proposes the optimal geographical locations for the PMUs in southern region Indian power grid for the implementation of SG, using Integer Linear Programming. The proposed optimal geographical locations for PMU placement can be a stepping stone for the implementation of SG in India.

关键词: phasor measurement units (PMUs)     smart grid (SG)     southern region Indian power grid (SRIPG)     integer linear programming (ILP)    

Tribological mechanism of carbon group nanofluids on grinding interface under minimum quantity lubrication

《机械工程前沿(英文)》 2023年 第18卷 第1期 doi: 10.1007/s11465-022-0733-z

摘要: Carbon group nanofluids can further improve the friction-reducing and anti-wear properties of minimum quantity lubrication (MQL). However, the formation mechanism of lubrication films generated by carbon group nanofluids on MQL grinding interfaces is not fully revealed due to lack of sufficient evidence. Here, molecular dynamic simulations for the abrasive grain/workpiece interface were conducted under nanofluid MQL, MQL, and dry grinding conditions. Three kinds of carbon group nanoparticles, i.e., nanodiamond (ND), carbon nanotube (CNT), and graphene nanosheet (GN), were taken as representative specimens. The [BMIM]BF4 ionic liquid was used as base fluid. The materials used as workpiece and abrasive grain were the single-crystal Ni–Fe–Cr series of Ni-based alloy and single-crystal cubic boron nitride (CBN), respectively. Tangential grinding force was used to evaluate the lubrication performance under the grinding conditions. The abrasive grain/workpiece contact states under the different grinding conditions were compared to reveal the formation mechanism of the lubrication film. Investigations showed the formation of a boundary lubrication film on the abrasive grain/workpiece interface under the MQL condition, with the ionic liquid molecules absorbing in the groove-like fractures on the grain wear’s flat face. The boundary lubrication film underwent a friction-reducing effect by reducing the abrasive grain/workpiece contact area. Under the nanofluid MQL condition, the carbon group nanoparticles further enhanced the tribological performance of the MQL technique that had benefited from their corresponding tribological behaviors on the abrasive grain/workpiece interface. The behaviors involved the rolling effect of ND, the rolling and sliding effects of CNT, and the interlayer shear effect of GN. Compared with the findings under the MQL condition, the tangential grinding forces could be further reduced by 8.5%, 12.0%, and 14.1% under the diamond, CNT, and graphene nanofluid MQL conditions, respectively.

关键词: grinding     minimum quantity lubrication     carbon group nanofluid     tribological mechanism    

Optimal redundant placement of PMUs in Indian power grid — northern, eastern and north-eastern regions

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

《能源前沿(英文)》 2013年 第7卷 第4期   页码 413-428 doi: 10.1007/s11708-013-0274-6

摘要: Effective utilization of renewable energy sources and efficient management of electric energy are essential for any developing countries like India. This can be envisioned through the implementation of concepts of smart grid (SG). One of the key requisites for SG implementation is that the grid should be completely observable. Renovation of conventional Indian power grid to a SG necessitates incorporation of the phasor measurement units (PMUs) in the present power grid measurement and monitoring system. Since the cost of PMU is high and any bus containing a PMU makes the neighboring connected buses observable, optimal placement of PMUs is very important for complete observability of the grid. This paper proposes optimal redundant geographical locations in the northern, eastern and north-eastern regions of Indian power grid for PMU placement. The PMUs installed in these geographical locations will make the grid completely observable and maintain the observability under the conditions of failure of some PMUs or branch outages. Integer linear programming has been used for finding the optimal PMU locations. The results proposed in this paper can be a stepping stone for revamping the Indian power grid to a SG ensuring complete observability during different contingency conditions.

关键词: phasor measurement unit (PMU)     smart grid (SG)     Indian power grid     northern region Indian power grid (NRIPG)     eastern region Indian power grid (ERIPG)     north-eastern region Indian power grid (NERIPG)     redundancy     integer linear programing (ILP)    

Performance of soft-hard-soft (SHS) cement based composite subjected to blast loading with consideration of interface

Jun WU,Xuemei LIU

《结构与土木工程前沿(英文)》 2015年 第9卷 第3期   页码 323-340 doi: 10.1007/s11709-015-0301-2

摘要: This paper presents a combined experimental and numerical study on the damage and performance of a soft-hard-soft (SHS) multi-layer cement based composite subjected to blast loading which can be used for protective structures and infrastructures to resist extreme loadings, and the composite consists of three layers of construction materials including asphalt concrete (AC) on the top, high strength concrete (HSC) in the middle, and engineered cementitious composites (ECC) at the bottom. To better characterize the material properties under dynamic loading, interface properties of the composite were investigated through direct shear test and also used to validate the interface model. Strain rate effects of the asphalt concrete were also studied and both compressive and tensile dynamic increase factor (DIF) curves were improved based on split Hopkinson pressure bar (SHPB) test. A full-scale field blast test investigated the blast behavior of the composite materials. The numerical model was established by taking into account the strain rate effect of all concrete materials. Furthermore, the interface properties were also considered into the model. The numerical simulation using nonlinear finite element software LS-DYNA agrees closely with the experimental data. Both the numerical and field blast test indicated that the SHS composite exhibited high resistance against blast loading.

关键词: high strength concrete (SHS)     engineered cementitious composite     interface     blast test     strain rate effect    

Recent advances in “universal” influenza virus antibodies: the rise of a hidden trimeric interface in

Yulu Wang, Dan Hu, Yanling Wu, Tianlei Ying

《医学前沿(英文)》 2020年 第14卷 第2期   页码 149-159 doi: 10.1007/s11684-020-0764-y

摘要: Influenza causes seasonal outbreaks yearly and unpredictable pandemics with high morbidity and mortality rates. Despite significant efforts to address influenza, it remains a major threat to human public health. This issue is partially due to the lack of antiviral drugs with potent antiviral activity and broad reactivity against all influenza virus strains and the rapid emergence of drug-resistant variants. Moreover, designing a universal influenza vaccine that is sufficiently immunogenic to induce universal antibodies is difficult. Some novel epitopes hidden in the hemagglutinin (HA) trimeric interface have been discovered recently, and a number of antibodies targeting these epitopes have been found to be capable of neutralizing a broad range of influenza isolates. These findings may have important implications for the development of universal influenza vaccines and antiviral drugs. In this review, we focused on the antibodies targeting these newly discovered epitopes in the HA domain of the influenza virus to promote the development of universal anti-influenza antibodies or vaccines and extend the discovery to other viruses with similar conformational changes in envelope proteins.

关键词: influenza virus     neutralizing antibody     hemagglutinin     globular head region     trimeric interface    

Experimental study on behavior of mortar-aggregate interface after elevated temperatures

Wan WANG, Jianzhuang XIAO, Shiying XU, Chunhui WANG

《结构与土木工程前沿(英文)》 2017年 第11卷 第2期   页码 158-168 doi: 10.1007/s11709-016-0374-6

摘要: A push-out test program was designed and conducted to study the meso-scale behavior of mortar-aggregate interface for concrete after elevated temperatures ranging from 20°C to 600°C with the concept of modeled concrete (MC) and modeled recycled aggregate concrete (MRAC). The MCs and MRACs were designed with different strength grade of mortar and were exposed to different elevated temperatures. Following that the specimens were cooled to room temperature and push-out tests were conducted. Failure process and mechanical behaviors were analyzed based on failure modes, residual load-displacement curves, residual peak loads and peak displacements. It is found that failure modes significantly depended on specimen type, the elevated temperature and the strength grade of mortar. For MC, major cracks started to propagate along the initial cracks caused by elevated temperatures at about 80% of residual peak load. For MRAC, the cracks appeared at a lower level of load with the increasing elevated temperatures. The cracks connected with each other, formed a failure face and the specimens were split into several parts suddenly when reaching the residual peak load. Residual load-displacement curves of different specimens had similarities in shape. Besides, effect of temperatures and strength grade of mortar on residual peak load and peak displacement were analyzed. For MC and MRAC with higher strength of new hardened mortar, the residual peak load kept constant when the temperature is lower than 400°C and dropped by 43.5% on average at 600°C. For MRAC with lower strength of new hardened mortar, the residual peak load began to reduce when the temperatures exceeded 200°C and reduced by 27.4% and 60.8% respectively at 400°C and 600°C. The properties of recycled aggregate concrete (RAC) may be more sensitive to elevated temperatures than those of natural aggregate concrete (NAC) due to the fact that the interfacial properties of RAC are lower than those of NAC, and are deteriorated at lower temperatures.

关键词: mortar-aggregate interface     push-out test     elevated temperatures     modeled concrete (MC)     modeled recycled aggregate concrete (MRAC)    

Hybrid optimization algorithm for modeling and management of micro grid connected system

Kallol ROY,Kamal Krishna MANDAL

《能源前沿(英文)》 2014年 第8卷 第3期   页码 305-314 doi: 10.1007/s11708-014-0308-8

摘要: In this paper, a hybrid optimization algorithm is proposed for modeling and managing the micro grid (MG) system. The management of distributed energy sources with MG is a multi-objective problem which consists of wind turbine (WT), photovoltaic (PV) array, fuel cell (FC), micro turbine (MT) and diesel generator (DG). Because, perfect economic model of energy source of the MG units are needed to describe the operating cost of the output power generated, the objective of the hybrid model is to minimize the fuel cost of the MG sources such as FC, MT and DG. The problem formulation takes into consideration the optimal configuration of the MG at a minimum fuel cost, operation and maintenance costs as well as emissions reduction. Here, the hybrid algorithm is obtained as artificial bee colony (ABC) algorithm, which is used in two stages. The first stage of the ABC gets the optimal MG configuration at a minimum fuel cost for the required load demand. From the minimized fuel cost functions, the operation and maintenance cost as well as the emission is reduced using the second stage of the ABC. The proposed method is implemented in the Matlab/Simulink platform and its effectiveness is analyzed by comparing with existing techniques. The comparison demonstrates the superiority of the proposed approach and confirms its potential to solve the problem.

关键词: micro grid (MG)     multi-objective function     artificial bee colony (ABC)     fuel cost     operation and maintenance cost    

Interface engineering for enhancing electrocatalytic oxygen evolution reaction of CoS/CeO heterostructures

《化学科学与工程前沿(英文)》 2022年 第16卷 第3期   页码 376-383 doi: 10.1007/s11705-021-2062-x

摘要: To realize renewable energy conversion, it is important to develop low-cost and high-efficiency electrocatalyst for oxygen evolution reaction. In this communication, a novel bijunction CoS/CeO2 electrocatalyst grown on carbon cloth is prepared by the interface engineering. The interface engineering of CoS and CeO2 facilitates a rapid charge transfer from CeO2 to CoS. Such an electrocatalyst exhibits outstanding electrocatalytic activity with a low overpotential of 311 mV at 10 mA∙cm−2 and low Tafel slope of 76.2 mV∙dec–1, and is superior to that of CoS (372 mV) and CeO2 (530 mV) counterparts. And it has long-term durability under alkaline media.

关键词: interface engineering     CoS/CeO2     electrodeposition     electrocatalyst     oxygen evolution reaction    

Behavior of compacted clay-concrete interface

R. R .SHAKIR, Jungao ZHU

《结构与土木工程前沿(英文)》 2009年 第3卷 第1期   页码 85-92 doi: 10.1007/s11709-009-0013-6

摘要: Tests of interface between compacted clay and concrete were conducted systematically using interface simple shear test apparatus. The samples, having same dry density with different water content ratio, were prepared. Two types of concrete with different surface roughness, i.e., relatively smooth and relatively rough surface roughness, were also prepared. The main objectives of this paper are to show the effect of water content, normal stress and rough surface on the shear stress-shear displacement relationship of clay-concrete interface. The following were concluded in this study: 1) the interface shear sliding dominates the interface shear displacement behavior for both cases of relatively rough and smooth concrete surface except when the clay water content is greater than 16% for the case of rough concrete surface where the shear failure occurs in the body of the clay sample; 2) the results of interface shear strength obtained by direct shear test were different from that of simple shear test for the case of rough concrete surface; 3) two types of interface failure mechanism may change each other with different water content ratio; 4) the interface shear strength increases with increasing water content ratio especially for the case of clay-rough concrete surface interface.

关键词: soil structure interaction     simple shear test     interface     friction     compacted clay     interface modeling    

Tracing the impact of stack configuration on interface resistances in reverse electrodialysis by in situ

《环境科学与工程前沿(英文)》 2022年 第16卷 第4期 doi: 10.1007/s11783-021-1480-9

摘要:

• RED performance and stack resistance were studied by EIS and LSV.

关键词: Reverse electrodialysis     Electrochemical impedance spectroscopy     Concentration polarization     Spacer shadow effect    

标题 作者 时间 类型 操作

Feedback linearization based control for weak grid connected PV system under normal and abnormal conditions

Rahul SHARMA,Sathans SUHAG

期刊论文

Effect of interface adhesion factor on the bearing capacity of strip footing placed on cohesive soil

期刊论文

Experimental verification of the interface wave method to detect interlaminar damage of a metal multilayer

Bing LI,Xu GENG,Tong LU,Lei QIANG,Minghang LI

期刊论文

Multi-objective optimization of surface texture for the slipperswash plate interface in EHA pumps

期刊论文

Thermal analysis of lubricated three-dimensional contact bodies considering interface roughness

期刊论文

Optimal placement of PMUs for the smart grid implementation in Indian power grid—A case study

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

期刊论文

Tribological mechanism of carbon group nanofluids on grinding interface under minimum quantity lubrication

期刊论文

Optimal redundant placement of PMUs in Indian power grid — northern, eastern and north-eastern regions

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

期刊论文

Performance of soft-hard-soft (SHS) cement based composite subjected to blast loading with consideration of interface

Jun WU,Xuemei LIU

期刊论文

Recent advances in “universal” influenza virus antibodies: the rise of a hidden trimeric interface in

Yulu Wang, Dan Hu, Yanling Wu, Tianlei Ying

期刊论文

Experimental study on behavior of mortar-aggregate interface after elevated temperatures

Wan WANG, Jianzhuang XIAO, Shiying XU, Chunhui WANG

期刊论文

Hybrid optimization algorithm for modeling and management of micro grid connected system

Kallol ROY,Kamal Krishna MANDAL

期刊论文

Interface engineering for enhancing electrocatalytic oxygen evolution reaction of CoS/CeO heterostructures

期刊论文

Behavior of compacted clay-concrete interface

R. R .SHAKIR, Jungao ZHU

期刊论文

Tracing the impact of stack configuration on interface resistances in reverse electrodialysis by in situ

期刊论文